9am - 5pm EST,  Monday - Friday

Home Page  |  Product Index  |  Ordering Info  |  Contact Us
Dissolved Oxygen Meters: HI 9143

 
Extended Range Dissolved Oxygen Meters
  • Rugged and waterproof, ideal for outdoor applications
  • Automatic calibration
  • Extended D.O. range

Measurements in the field can subject instrumentation to the inclemency of weather. Cold, rain, snow, dust and humidity, associated with use in the field, can cause condensation which may damage a meter, rapidly deteriorating its performance and life. HI 9143 is designed for harsh outdoor applications, especially waste water treatment and fish farming. Simple on-site calibration requires no chemical solutions. Just expose the probe to air and press the CAL button. In a few minutes, the meter is calibrated and ready to use. Auto-calibration eliminates the need to use a screwdriver or other devices to adjust the reading. The new and improved HI 9143 measures and displays O2 from 0 to 300%, 0 to 45 mg/L and temperature from 0 to 50 °C. The HI 9143 also supplies the user with compensation of salinity, altitude factors and temperature effect.

HI 9143 is supplied complete with D.O. probe HI 76407/4 with 4 m (13') cable, 2 spare membranes, electrolyte solution HI 7041S (30 mL), batteries, rugged carrying case and instructions. 

 

Available Accessories:
HI 7041S | Refilling electrolyte solution (30 mL)
HI 710005 | 110V to 12VDC adapter
HI 710006 | 220V to 12VDC adapter
HI 76407/4 | D.O. probe with 4 m (13') cable
HI 76407/10 | D.O. probe with 10 m (33') cable
HI 76407/20 | D.O. probe with 20 m (67') cable
HI 76407A/P | Pack of 5 replacement membranes
HI 721317 | Rugged carrying case
 
Specifications:  
Range Oxygen
  0.00 to 45.00 mg/L
Range % Saturation Oxygen
  0.0 to 300.0%
Range Temperature
  0.0 to 50.0 °C
Resolution Oxygen
  0.01 mg/L
Resolution % Saturation Oxygen
  0.1%
Resolution Temperature
  0.1°C
Accuracy (@20°C/68°F)
  ±1.5% Full Scale (Oxygen); ±0.5°C (Temp)
Calibration
  Automatic in saturated air
Temp. Compensation
  Automatic from 32 to 122°F (0 to 50°C)
Auto Altitude Compensation: 
  0 to 1900m (0 to 6230')
Resolution: 
  100 meter
Auto Salinity Compensation: 
  0 to 40 g/L (ppt)
Resolution: 
  1 g/L (ppt)
Probe
  HI 76407/4 Polarographic D.O. probe
Battery Type / Life
  4 X 1.5 Volt AA / Power plug for 12VDC supply/ approx. 200 hours of continuous use
Environment
  32 to 122°F (0 to 50°C)
Dimensions
  7.7 x 3.1 x 2.4" (196 X 80 X 60mm)
Weight
  3.1 lb (1.4 Kg)
 


Miller Analytical | 3158 Fairway Ave | Bristol | PA | 19007