Multiparameter Water Quality Meter
  • Display up to 12 parameters
  • Graphic LCD with backlight
  • Meter features IP67 and probe features IP68 waterproof protection

HANNA's new HI 9828 is a multiparameter portable instrument that monitors up to 13 different water quality parameters (6 measured, 7 calculated). The meter has a 128 x 64 pixel dot matrix backlit LCD that automatically sizes the digits and allows full configuration of each parameter measured, units and language selection, and on-screen graphing. Each parameter is fully supported by the on-screen context sensitive help both in the calibration mode and during measurement. For monitoring and recording data, HI 9828 is equipped with HANNA's exclusive T.I.S. Tag Identification System: iButton©s with unique ID numbers can be installed at various sampling sites and are used to record specific location information when logging. The meter incorporates comprehensive GLP features, and download of data is done via USB connectivity. Designed for outdoor environments, the meter is impact resistant and waterproof to IP67 standards (30 minutes immersion under 1 m of water). The multi sensor probe can be left underwater (IP68 standard). For field calibration, HANNA's Quick Calibration allows the user to standardize pH, conductivity and oxygen with one solution.

HI 9828 is supplied with HI 769828 DO/EC/Temperature probe; HI 9828-25 quick calibration standard solution, 500 mL; probe maintenance kit; 4 rechargeable C size, Ni-MH batteries; power adapter & cable; car 12V accessory outlet adapter; (5) iButton©s with holder; HI 7698281 USB interface cable; HI 92000 Windows® compatible software and instruction manual in a rugged carrying case.

 
 

Available Accessories:
Coming Soon |  
 
Specifications:  
Range (pH)
  0.00 to 14.00 pH
Resolution (pH)
  0.01 pH
Accuracy (pH)
  ±0.02 pH
Range (mV of pH input)
  ±600.0 mV
Resolution (mV of pH input)
  0.1 mV
Accuracy (mV of pH input)
  ±0.5 mV
Range (ORP)
  ±2000.0 mV
Resolution (ORP)
  0.1 mV
Accuracy (ORP)
  ±1.0 mV
Range (Dissolved Oxygen)
  0.0 to 500.0% / 0.00 to 50.00 mg/L
Resolution (Dissolved Oxygen)
  0.1% / 0.01 mg/L
Accuracy (Dissolved Oxygen)
  0.0 to 300.0%: ±1.5% of reading or ±1.0% whichever is greater; 300.0 to 500.0%: ±3% of reading; 0.00 to 30.00 mg/L: ±1.5% of reading or 0.10 mg/L whichever is greater; 30.00 mg/L to 50.00 mg/L: ±3% of reading
Range (Conductivity)
  0.000 to 200.000 mS/cm (actual EC up to 400 mS/cm)
Resolution (Conductivity)
  Manual: 1 µS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm; 1 mS/cm Automatic: 1 µS/cm from 0 to 9999 µS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm ; 0.1 mS/cm from 100.0 to 400.0 mS/cm Automatic mS/cm: 0.001 mS/cm from 0.000 to 9.999 mS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm
Accuracy (Conductivity)
  ±1% of reading or ±1 µS/cm whichever is greater
Range (Resistivity)
  0 to 999999 Ocm; 0 to 1000.0 kOcm; 0 to 1.0000 MOcm
Resolution (Resistivity)
  Dependent on resistivity reading
Range (TDS)
  0 to 400000 mg/L or ppm (the maximum value depends on the TDS factor)
Resolution (TDS)
  Manual: 1 mg/L (ppm); 0.001 g/L (ppt); 0.01g/L (ppt); 0.1 g/L (ppt); 1 g/L (ppt) Auto-range scales: 1 mg/L (ppm) from 0 to 9999 mg/L (ppm); 0.01 g/L (ppt) from 10.00 to 99.99 g/L (ppt); 0.1 g/L (ppt) from 100.0 to 400.0 g/L (ppt) Auto-range g/L (ppt) scales: 0.001 g/L (ppt) from 0.000 to 9.999 g/L (ppt); 0.01 g/L (ppt) from 10.00 to 99.99 g/L (ppt); 0.1 g/L (ppt) from 100.0 to 400.0 g/L (ppt)
Accuracy (TDS)
  ±1% of reading or ±1 mg/L
Range (Salinity)
  0.00 to 70.00 PSU (extended Practical Salinity Scale)
Resolution (Salinity)
  0.01 PSU
Accuracy (Salinity)
  ±2% of reading or 0.01 PSU whichever is greater
Range (Seawater Specific Gravity)
  0.0 to 50.0 st, s0, s15
Resolution (Seawater Specific Gravity)
  0.1 st, s0, s15
Accuracy (Seawater Specific Gravity)
  ±1 st, s0, s15
Range (Atm. Pressure)
  450 to 850 mmHg; 17.72 to 33.46 inHg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa
Resolution (Atm. Pressure)
  0.1 mmHg; 0.01 inHg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa
Accuracy (Atm. Pressure)
  ±3 mmHg within ±15°C from the temperature during calibration
Range (Temp)
  -5.00 to 55.00°C; 23.00 to 131.00°F; 268.15 to 328.15K
Resolution (Temp)
  0.01°C; 0.01°F; 0.01K
Accuracy (Temp)
  ±0.15°C; ±0.27°F; ±0.15K
Calibration (pH)
  Automatic 1, 2, or 3 points with 5 memorized standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or 1 custom buffer
Calibration (ORP)
  Automatic at 1 custom point
Calibration
  Automatic 1 point with 6 memorized standards (84 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point
Calibration
  Automatic 1 or 2 points at 0, 100% or 1 custom point
Calibration
  Based on conductivity or salinity calibration
Calibration
  Automatic at 1 custom point
Calibration
  Automatic at 1 custom point
Temperature Compensation
  Automatic from -5 to 55°C (23 to 131°F)
Logging Memory
  Up to 60000 samples with 13 measurements each
Logging Interval
  1 second to 3 hours
Computer Interface
  USB (with HI 92000 software)
Waterproof Protection
  Meter IP67, Probe IP68
Environment
  0 to 50°C (32 to 122°F); RH 100%
Power Supply
  (4) 1.5V alkaline C cells (approx. 150 hours of continuous use without backlight)/ (4) 1.2V rechargeable C cells (approx. 70 hours of continuous use without backlight)
Dimensions
  Meter: 221 x 115 x 55 mm (8.7 x 4.5 x 2.2); Probe: 270 x 46 mm DIA (10.6 x 1.8 DIA)
Weight
  Meter: 750g (26.5 oz.); Probe: 750g (26.5 oz.)