Combo - Waterproof pH / EC / TDS / °C / °F Testers with
Replaceable Electrode
- Rugged, Floating Waterproof Casing.
- Temperature in °C and °F.
- Measurement Stability Indicator.
- Replaceable pH Electrode Featuring an Extendable Junction.
- Automatic pH Calibration at standard as well as NIST Buffer
Sets.
- Automatic Temperature Compensation (ATC).
- Adjustable Temperature Coefficient Factor.
- Specifications
|
|
The new waterproof HI 98129 & HI 98130 Combo
testers from Hanna are designed for high accuracy pH, EC/TDS and temperature
measurements. No more switching meters to measure the pH and then the EC or
TDS of a solution. At startup, Combo performs a self check then
displays the remaining battery level to assure proper working condition.
These testers also have a stability indicator and hold feature to prompt the
user when to take the reading & freeze the display for easy and accurate
recording. Calibration and temperature compensation is automatic, while the
EC / TDS conversion factor and temperature coefficient factor (ß) are user
adjustable for application specific measurements. For calibration in pH, the
user may choose between standard or N.I.S.T. buffer sets. The combo has a
replaceable pH electrode cartridge with an extendable cloth junction as well
as an EC/TDS graphite electrode which resists contamination by salts and
other substances that come in contact with the electrode. These new pH / EC
/ TDS / Temperature meters have a stainless steel temperature probe for
faster and more precise temperature measurement. Fast, efficient, accurate
and portable, the Combo pH, EC/TDS and temperature tester meets the
requirements of your routine multi-measurements.
 |
Replaceable pH electrode cartridge
featuring an extendable junction. |
Choose your Combo according to the proper EC / TDS ranges for your
application:
- HI 98129; EC - 0 to 3999 µS/cm; TDS - 0 to 2000
ppm
- HI 98130; EC - 0.00 to 20.00 mS/cm; TDS - 0.00 to
10.00 ppt
Combo is supplied complete with HI 73127 pH electrode, 4 x 1.5V
batteries and electrode replacement tool (HI 73128).
| Specifications: |
|
HI 98129 |
HI 98130 |
| Range |
EC |
0 to 3999 µS/cm |
0.00 to 20.00 mS/cm |
| |
TDS |
0 to 2000 ppm |
0.00 to 10.00 ppt |
| |
pH |
0.00 to 14.00 pH |
|
Temperature |
0.0 to 60.0 °C or 32.0 to 140.0 °F |
| Resolution |
EC |
1 µS/cm |
0.01 mS/cm |
| |
TDS |
1 ppm |
0.01 ppt |
| |
pH |
0.01 |
| |
Temperature |
0.1 °C or 0.1 °F |
| Accuracy (@ 20°C/68°F) |
EC/TDS |
±2% F.S. |
| |
pH |
±0.05 |
| |
Temperature |
±0.5 °C or ±1 °F |
| Typical EMC Deviation |
EC/TDS |
±2% F.S. |
| |
pH |
±0.02 |
| |
Temperature |
±1 °C or ±1 °F |
| Calibration |
EC/TDS |
Automatic at 1 point |
| |
pH |
1 or 2 points with 2 sets of memorized
buffers:
(pH 4.01, 7.01 & 10.01 or 4.01, 8.68 & 9.18) |
| Temperature Compensation |
EC/TDS |
BETA (ß)
= adjustable from 0.0 to 2.4 per °C in increments of 0.1 |
| |
pH |
Automatic |
| EC / TDS Conversion Factor |
|
Adjustable from 0.45 to 1.00 |
| Environment |
|
0 to 50°C (32 to 122°F);
R.H. 100% |
| Battery Type / Life |
|
4 x 1.5V / 100 hours |
| Auto Shut-off |
|
After 8 minutes |
| Dimensions |
|
163 x 40 x 26 mm (6.4 x 1.6 x
1.0") |
| Weight |
|
85 g (3 oz.) |
|